Fan airflow is weak although cooling pipes become cold
Cold refrigeration pipes with weak vent delivery do not prove the whole A/C system is functioning normally. Airflow can be limited by the filter/intake, blower, evaporator or distribution system, and pipe temperature alone does not identify which one.
Describe when delivery weakens
Record all settings, affected vents and time to fade. Compare blower sound with air volume. Inspect accessible filter and intake conditions; an immediate restriction differs from airflow that progressively falls during A/C operation.
Compare motor response and air path
A workshop should assess motor speed/control and current while the fault exists. Falling speed directs attention towards electrical supply or the motor; steady operation with reduced delivery requires inspection of air passages, flaps and the evaporator.
If switching A/C off while ventilation continues later restores airflow, icing is a possibility to test through temperature sensing and refrigeration operation. Do not add refrigerant because one pipe feels cold, or replace a blower merely because it is the audible component.
Verify through the original duration
Correct the demonstrated restriction, electrical or cooling-control fault and check condensate drainage where relevant. Run the system long enough to expose a progressive failure. A short workshop restart may appear normal while the original problem remains.
Outcome & verification
Confirm sustained air delivery, appropriate cooling and normal drainage under comparable conditions. State temporary recovery as an observation, not a repair.