Airflow weakens while the blower sound stays strong
Strong blower sound with progressively weaker vent delivery suggests an air-path or distribution problem as well as a possible motor issue. If airflow recovers after cooling is switched off, evaporator icing is a possibility that requires testing.
Observe the fade precisely
Record time to failure, A/C state and which outlets weaken. Inspect the cabin filter and intake safely. A filter generally restricts from the outset, while progressive loss suggests an additional changing condition; neither pattern alone is conclusive.
Compare motor speed with air delivery
A workshop should assess blower control and current while the fault exists. If the motor slows, investigate its supply/controller. If it remains steady, inspect the air path, evaporator and flap operation rather than replace the motor because it is audible.
For suspected icing, assess evaporator sensing and refrigeration operation with the correct equipment. Do not add refrigerant solely because airflow is poor. Check condensate drainage separately where wetness or retained water is present.
Repeat a comparable operating period
Correct the demonstrated restriction, control or refrigeration problem and run long enough to reproduce the original time-dependent event. A short restart test can miss a fault that appeared only after sustained A/C use.
Outcome & verification
Confirm sustained airflow and cooling with appropriate drainage. Temporary recovery after stopping A/C remains diagnostic evidence, not a completed repair.