J11 stops cooling again soon after a recharge
A/C fading again soon after recharge requires a leak/control assessment rather than another automatic top-up. The previous recovered and charged quantities are more useful than a receipt saying gas was added.
Establish the service baseline
Record time to fade, ambient conditions and whether airflow remains normal. Obtain the previous leak-test findings and identify the exact refrigerant/system. Condenser damage is a candidate, not proof from the J11 model name alone.
Compare retention and operation
An A/C workshop should use an approved leak-detection method and evaluate pressures, temperatures and compressor control. A small leak may not be visible unaided. If charge quantity is appropriate, investigate fan/condenser airflow, sensing and air blending rather than add more refrigerant.
Inspect service ports and disturbed joints without assuming the previous service introduced the defect. A rotating pulley does not establish delivery on every compressor arrangement. One static pressure reading cannot establish the correct charge.
Repair before another recharge
Correct the demonstrated leaking boundary or control defect and evacuate/charge to the exact specification. Avoid leak-seal additives that can complicate equipment and diagnosis. Run long enough to expose the original warm fade and retain a follow-up retention check.
Outcome & verification
Confirm sustained cooling, appropriate operation and no renewed leak evidence over a suitable interval. Immediate cold air alone is not a retention result.